Support Center
Welcome! How can we help?
Our support center contains educational resources including how-to tutorials, frequently asked questions and helpful reference documents.
TUTORIALS
Watch step-by-step video tutorials about key pump features.
DOCUMENTS
Weʼve gathered essential documents here for your convenience.
FAQ's
Find answers to your most pressing questions.
Need immediate assistance?
Call 844-566-4968 to speak with a tech support agent. We are available 24/7.
How-To Tutorials
FAQs
Getting Started
Can I use the pump without an IV pole?
Yes. The holster allows you to clip the pump to a belt, bag, or other surface for hands‑free, on-the-go use. The pump can also be used entirely on its own without the holster or pole clamp if you prefer to carry or position it differently.
What comes with the Luminoah Flow System?
What additional items do I need to begin feeding?
How do I turn the pump on and off?
Press and hold the Sleep / Wake button on top of the pump to turn the pump on or wake it from deep sleep. When the pump is in deep sleep, you may need to hold the button slightly longer. To power off, open the Settings menu (gear icon in top right corner of the screen) and select Power Off.
What do the LED status light colors mean?
A solid orange LED indicates the pump is charging; the LED turns off once fully charged. A solid green LED indicates normal operation, while a flashing green LED means a feed is paused. Yellow or red LEDs only appear when a notification or alarm needs attention.
How do I attach the Pump Head correctly?
How do I fill the Nutrition Pouch?
Remove the pouch cap, thread the funnel securely onto the pouch, and pour formula or water at a steady pace. Avoid splashing or rapid pours to help limit foaming. Thicker or more viscous formulas may flow more slowly through the funnel, so allow extra time when filling.
How do I prevent air from getting trapped in the pouch?
Can I prefill pouches ahead of time?
You may prefill pouches if you follow the storage and handling instructions provided by your clinician or formula manufacturer. However, each Administration Set, including the pouch, is intended for a maximum use period of 24 hours, so any prefilled pouch must still be used within the same 24‑hour window.
How do I set the Amount and Flow Rate?
What is a Quick Feed?
Quick Feed is the method to program a single feeding session from the Main Menu. Enter the Amount of water or nutrition and Flow Rate for the feed.
How do presets work?
Presets allow you to save up to 4 pre‑programmed feeding and 4 pre‑programmed hydration settings for convenience. Presets are helpful if feeding amounts or rates change throughout the day or night. Simply swipe right to select the preset desired instead of re‑entering the values on the Quick Feed screen.
What happens if I forget my lockout code?
If you forget the lockout code, unlock the pump using the universal override code 1010. After unlocking, go to Settings to set a new passcode, using 1010 as the current passcode when prompted.
Why must I prime before connecting to my body?
Priming ensures that the tubing is completely filled with fluid so no air enters your feeding tube.
Why does the pump stop every 10 seconds to ask if I see drops?
The pump pauses briefly as a safety check to confirm that fluid has reached the end of the tubing. This step helps limit formula waste by preventing continuous priming if you forget to stop it. Once you see drops, you can stop priming and proceed to connect to your feeding tube.
What should I do if priming does not complete?
Ensure the pouch is upright and that the spike connector and Pump Head are fully attached. Also confirm that you pressed excess air out of the pouch during setup. If air remains inside, priming may take significantly longer. If you still do not see drops after several cycles, replace the Administration Set and start priming again.
How do I begin a feed once connected?
After you connect the tubing to the feeding tube, verify that the Amount and Flow Rate shown on the screen match what your clinician prescribed. When ready, select Start Feed to begin delivery. You can also start the feed by holding the Sleep / Wake button for three seconds once you have completed the priming steps and reached the feeding screen.
Can I pause or resume a feed?
Yes. To pause or resume a feed either select Pause or Resume on the screen, or hold the Sleep / Wake button for three seconds while a feeding session is active. A flashing green LED indicates a paused feed.
Will the pump remember progress if interrupted?
Yes. The pump records the volume already delivered in its history. If a feed ends unexpectedly, the pump will display a Feed Interrupted alarm showing how much volume remains and the rate you were using. You can then re‑enter the remaining amount and resume feeding as instructed by your clinician.
How often should I replace the Administration Set?
Each Administration Set, including the Nutrition Pouch, tubing, and Pump Head, must be replaced every 24 hours.
When should I use the Rinse feature?
Use the Rinse feature when you plan to reuse the same Administration Set for another feed within the 24‑hour period, or when you want to clear formula from the tubing between uses. In this system, rinsing refers to clearing the tubing only—it does not deliver water to your body.
Can I use non-Luminoah administration sets?
No. The pump is designed to work only with Luminoah Flow Administration Sets. Other sets may not attach securely or may lead to free‑flow, inaccurate delivery, or safety alarms.
Do I need to flush the system after every feed?
Can I rinse and reuse a set within the same 24 hours?
What types of formulas can I use?
You should use commercially prepared enteral nutrition formulas that are prescribed or recommended by your clinician. These formulas have consistent composition and thickness, which helps ensure safe, accurate delivery by the pump.
Can I use homemade blenderized or thickened foods?
No. Homemade blenderized, or thickened foods can vary widely in texture and consistency, which may interfere with safe pump operation or accuracy. Only commercially prepared formulas should be used with the system.
Why are lipids not permitted?
The device has not been validated with formulas containing added lipids or high‑fat emulsions.
Can a cold formula be used?
Yes. Cold formulas can be used, but very cold formulas may create small air bubbles as they warm, which can increase the chance of an "Air‑in‑Line" alarm. Allowing formulas to reach room temperature can help reduce bubbles. If bubbles or foaming appear during a feed, you can pause the session and use the Prime option to clear air from the tubing before resuming.
What do the LED colors mean?
A red flashing LED indicates a high-priority alarm that requires immediate attention. A yellow flashing LED indicates a medium-priority alarm, and a solid yellow LED indicates a low-priority notification. A solid green LED shows normal operation, while a flashing green LED means a feed is paused.
What should I do if I get an Upstream Occlusion alarm?
An "Upstream Occlusion" Alarm means formula is not moving from the Nutrition Pouch into the pump. Check that the pouch is not empty, the spike connector is fully tightened, and the tubing between the pouch and pump is not kinked or blocked. Reattaching these components will usually resolve the issue. If air has entered the tubing as a result of the upstream occlusion, prime out the air from the Pause screen, and resume the feeding session.
What should I do if I get a Downstream Occlusion alarm?
A "Downstream Occlusion" Alarm means formula is not flowing from the pump to your feeding tube. Check for kinks in the extension set, closed clamps, or a clogged tube. Straighten the tubing or clear the blockage before restarting the feed.
What should I do if I get an Air‑in‑Line alarm?
An "Air‑in‑Line" Alarm means the pump has detected a large amount of air in the tubing. Pause the feed and use the Prime option to push air out of the tubing. Once fluid is flowing smoothly again, you can resume your feed.
What should I do if I get a Feed Interrupted alarm?
A "Feed Interrupted" Alarm appears if the pump stops or restarts during an active feed. The screen will show how much volume remains and the rate you were using. Re‑enter the remaining volume and resume feeding as instructed by your clinician.
What should I do if I see an Insufficient Charge notification?
This means the battery may not last long enough to finish the feed. You can still start or continue feeding, but plan to plug the pump in during the feeding session so it has enough power to complete the feed.
How do I clean the pump?
Wipe the outside of the pump with a cloth dampened with a mild soap‑and‑water solution per the User Guide. Make sure no liquid enters the device and never submerge the pump in water.
How do I clean the funnel?
Rinse the funnel right after use to prevent formula buildup. If necessary, soak it in warm, soapy water, scrub gently soft brush (e.g., nylon bristled bottle brush or similar), rinse well, and let it air dry as described in the User Guide.
How often should I clean the pump?
It is recommended that the pump be cleaned daily to help keep the device free of residue and operating properly. Users may find that the need for cleaning varies based on their routine, but cleaning after each Administration Set use is the guidance provided in the User Guide.
How do I clean the power adapter?
Clean the power adapter only when necessary. Unplug it first, then wipe the exterior with a cloth lightly dampened with 70% isopropyl alcohol.
What should I do if formula leaks into the pump?
Stop using the pump, wipe away visible residue, and allow the device to dry completely. If the device stops operating normally and or causes unexpected alarms, stop using the device immediately, and contact Customer Support at 1-844-566-4968.
How do I attach the holster?
Align the back of the pump with the holster and press gently until the magnetic connection clicks into place. The pump should be positioned with the buttons on top, and the holster logo should face upright and be readable when oriented correctly.
How do I attach the Pole Clamp securely?
Does the setup of the pump affect accuracy?
The pump can operate in any orientation as a result of our 360° Nutrition Delivery™ design.
How long does the battery last?
The battery is designed to last a minimum of 24 hours at a rate of 125ml/hr. Battery life will vary based on individual feeding schedules, programmed flow rates, the use of the mobile application (optional), and the screen brightness level.
How long does it take to recharge?
Using the provided charger, the pump recharges from 0% to 100% in about 4.5 hours.
Can I feed while charging?
Yes. The pump can operate normally while it is plugged in and charging.
How will I know if the battery is failing?
If the pump no longer holds a charge or charging does not restore normal battery life, contact Customer Support at 1-844-566-4968.
Who can use the pump?
The pump is intended for adults and for children 2 years of age and older who require enteral nutrition. It should not be used for neonates.
What should I do in case of a power outage?
If the pump cannot be powered or charged, you may need to use an alternative feeding method such as a gravity bag or syringe, as instructed by your clinician. Keep backup supplies available so you can continue feeding safely.
Is BluetoothⓇ required for feeding?
Why does my feed seem slower than expected?
A feed may run slower for a number of reasons. A very cold formula can thicken slightly and move more slowly, and kinks or tight bends in the tubing can also reduce flow. Make sure the programmed rate is correct, the tubing is straight, and the formula has had time to warm to room temperature. If feeding still seems unusually slow, reach out to your clinician or Customer Support at 1-844-566-4968 for guidance.
Why do small bubbles appear in the tubing?
Small bubbles are normal and usually do not affect feeding. Larger bubbles or foam may appear if the formula is very cold or shaken. To help resolve bubbles, pause the feed and use the Prime option which can help clear excess air.
Why is my screen dim or turning off?
This may happen if the screen brightness is set low or the pump is entering sleep mode to save battery. You can adjust brightness or wake the screen by pressing the Sleep / Wake button on the top of the pump.
Why does the pump ask me to verify settings after pausing?
The pump asks you to confirm settings after a pause to prevent unintentional changes and ensure you resume the correct programmed feed.
Why am I unable to pair with the pump?
- Confirm Bluetooth® is enabled on your mobile device
- Ensure the correct pairing code is entered
- Verify the pump is powered on and ready for pairing
- Restart the pairing process from the application
Note: If you have paired a pump previously:
-
- Navigate to the Bluetooth® settings on your phone’s settings
-
- Locate “Luminoah Flow” in the listed devices
-
- Click the device and remove the device from the list
-
- Restart the Luminoah Application and proceed through the pairing steps
Why do I not see a 6-digit code during pairing?
- Force close the app and restart the mobile application.
- Restart the Luminoah Flow pump. To turn the pump off either hold down the Sleep / Wake button on top of the pump for 10 seconds or navigate to the Settings (gear icon) on the top right of the screen and select "Power Off". Wait 5 seconds and turn the pump back on by holding down the Sleep / Wake button on top of the pump.
- Repeat the pairing process.
What do I do if the application is not responding or crashing?
- Close and reopen the application.
- Ensure your device meets compatibility requirements.
- Restart your mobile device if the issue persists.
Why can’t I login to the application?
Verify your email and password are entered correctly. If you have forgotten your password, use the password reset option.
Why is my data not updating as expected?
- Ensure your mobile device has an active internet connection.
- Confirm Bluetooth® is enabled and the pump is within range.
- Check the “Last Updated” timestamp in the application.
- Close and reopen the application if needed.
Why is my data incomplete or missing?
- Check connections status to ensure Bluetooth is on and connected to the pump.
- Open the application and allow time for data to synchronize.
- Refresh by pulling down on the Home Screen.
This tutorial may open best in a new tab.
Open tutorial